Lookup Value?: Visitor Bathroom

From Lookup Field?: AccessibilityFeatures Lookups

Definition (May contain conditions that must apply)

Bathroom that is closest to Common Area. Minimum half bath. Door has minimum 32-inch clear width opening; lever handles. Minimum 60-inch turnaround or other approved turnaround configuration (30" x 48" clear space if door opens out.). Grab bar installed in toilet area with proper blocking. This is required to be considered Visitable. 

Synonym(s)? 

Lookup Status Change Date?: Aug 09 2017

Revised Date?: Jan 10 2018

Added in Version?: 1.6.0

Spanish (Lookup Field)?: CaracterísticasDeAccesibilidad

Spanish (Lookup Value)?: Sala de Baño de Visitas